How to load a Civil 3D pipe network into HydraStorm for hydraulic analysis.
The dropdown in the toolbar lists all pipe networks in the current drawing. Select a network from the dropdown to load it into HydraStorm.
HydraStorm re-reads the drawing each time a network is selected. After creating or modifying pipe networks in Civil 3D, re-select the network from the Network dropdown to pick up the changes.
When you load a network, HydraStorm reads the following data from Civil 3D:
HydraStorm tracks Civil 3D objects by their persistent handle (C3dHandle), which survives across sessions. This means your HydraStorm project file (.hsp) stays linked to the correct objects even after saving and reopening the drawing.
Each drawing can contain multiple pipe networks. HydraStorm works with one network at a time. To switch networks, select a different network from the dropdown.
HydraStorm handles pipe networks that contain disconnected branches. Each sub-network is calculated independently and requires its own downstream boundary condition (normal depth, user-specified elevation, or (Dc + D) / 2).
HydraStorm reads from the Civil 3D drawing at load time. If you modify the pipe network in Civil 3D after loading, re-select the network from the Network dropdown to re-read the current geometry.